JM Science Inc.
AQUACOUNTER
JM Science’s AQUACOUNTER Coulometric AQ-300 KF Titrator is designed for the biodiesal in alternative fuels industry. It has six built-in calculation modes to accommodate solid, liquid and gas samples. It determines moisture down to 1ppm with just a simple injection of the sample. A built-in detector monitors titration status. Four files with preset conditions can be stored in memory and allows instant recall of data for up to 20 samples. The unit is CE approved, has an international voltage input (100-240V) and results may be printed on an optional printer or downloaded to a PC. Includes download software for laptop or PC.
City Technology
4CM Carbon Monoxide Sensor
City Technology's 4CM, carbon monoxide sensor was developed to meet the most stringent toxic gas and mining standards. The 4CM improves the functionality, reliability and effectiveness of PPE in hostile environments, by responding 12 percent faster to CO hazards and recovering in over half the time of the industry average. It has a typical T90 time of seven seconds and a recovery time to an indicated level of less than 2ppm in less than 100 seconds. During 50-day exposures in 120°F and 11 percent relative humidity, and 120°F at 95 percent relative humidity, the 4CM operated to specification. The sensor provides excellent accuracy and stability at high and low gas concentrations, meeting the EN45544 requirements for uncertainty, typically achieving 1ppm for zero concentrations and less than 1 percent variation at 250, 750 and 1000ppm.
Bilco
CNIguard Intrusion Detection System
CNIguard intrusion detection system is designed to protect access points in drinking water distribution systems against the threat of intentional contamination. The system utilizes a patented Smart Sensing Technology to detect tampering such as drilling, grinding and cutting; while virtually eliminating costly false alarms. The computerized system can distinguish between real threats and common occurrences such as heavy rain, hail, etc. and is rated for a maximum of one false alarm per year. CNIguard does not rely on human interpretation to determine if a threat is real.
Bio-Mod Modular Bioretention System
The Bio-Mod Modular Bioretention System is a modular pre-cast concrete bio-filtration cell system developed to add consistency to design and construction, with features to enhance filter performance, structural integrity, reduced construction and on-going maintenance costs. Designed for use with local agency bioretention cell designs, Bio-Mod is compatible for use with all types of filter soils, including non-proprietary low-flow (5 to 10 inches an hour) or high-flow soils.
Control Co.
Control Pen
Control Company's new Counter Pen is a combination marker and digital counter designed for the lab and plant. Each time a black mark is made with the felt-tipped pen, it automatically sounds a beep, and LCD displays the counts. Use it to count cell growth on petri dishes, inventory parts, and tally samples received.
General Monitors
Ultrasonic Gas Leak Detector
General Monitors’ Gassonic Observer is now FM- and CSA-certified, which means the detector has been evaluated through independent scientific testing and found to be safe and reliable. The detector features a microphone and a detection radius of up to 20 meters at a leak rate of 0.1 kg/s. In addition, the detector offers the Senssonic integrated acoustic self-test, which periodically verifies the integrity of the electronic circuitry and the operation of the acoustic sensor.
ADS_LLC
Leak Listening System
ADS’ Hykron Leak Listening System provides high acoustic sensitivity for checking leak noises. As leak noise travels through water and a pipe wall, it can be detected by listening at valves, hydrants, or any available fitting on the pipe. The device detects leak noise through its highly sensitive, built-in electronic sensor. It comes packaged in a carry case with handheld electronic sensor, amplifier with belt attachment, extension rods, magnet attachment and high quality headphones.
Photovac, Inc.
Ethanol Leak Detection
Photovac’s 2020ComboPRO uses photoionization detection technology to detect ethanol leaks in fuel ethanol plants. The measurement of ethanol leaks in fuel ethanol production facilities is essential for compliance with the air quality operating permit requirements of NSPS Subpart VV. A large digital display prompts the operator through basic operations, and critical data is displayed in less than three seconds. It boasts a wide measurement range of 0.1 ppm to 10,000 ppm, and alarms alert the operator when pre-defined limits are exceeded.
MSA Worldwide
Automated Test System
The Altair 5 Galaxy Automated Test System, MSA’s automated record-keeping and calibration system for MSA portable gas detection instruments, is now available for both Altair 4 and Altair 5 Multigas Detectors. This family of products also includes Solaris, Orion and Sirius Multigas Detectors, the Orion
plus IR Detector and Altair Single-Gas Detectors.
MSA Worldwide
Portable Gas Detector
The Altair 4 Multigas Detector received EU toxic gas approval on Dec. 19, 2008, as performance compliant for measurement of 0-200 ppm hydrogen sulfide gas and 0-999 ppm carbon monoxide gas. Test conditions used appear in standards EN 45544-1:1999 and EN 45544-2:1999. This unit for lower explosive limit, carbon monoxide, hydrogen sulfide, and oxygen is the only portable gas detector with an optional MotionAlert feature, which is useful should a user become disabled due to unforeseen hazards.
Photovac, Inc.
Flame Ionization Detector
Photovac Inc.’s DataFID flame ionization detector features a built-in Bluetooth device to transfer data wirelessly to a PDA or computer. A metal hydride hydrogen fuel cylinder supplies up to 70 hours of continuous use. The hydrogen cylinder is UN3468 classified. An optional supplemental air tank provides readings in high concentration environments up to 100,000 ppm and in oxygen deprived locations such as high altitudes. The DataFID exceeds the requirements of EPA Method 21 for fugitive emissions.
InterOcean Systems Inc.
Oil Spill & Leak Detection Systems
Slick Sleuth Oil Spill Detection & Alarm Systems are used for immediate detection, early warning alert, containment and prevention of accidental spills. The optical sensor detects small amounts of oil and can be configured to automatically shut off pumps or valves, activate alarms and provide remote alert notification. The non-contact design is ideal for remote deployment in rugged settings such as coastal areas, harbors, inland waterways, industrial spillways, boiler and engine-generator rooms, sumps and separators.
General Monitors
Toxic Gas Detector
The TS4000H Intelligent Toxic Gas Detector from General Monitors is compatible with HART communication protocol. The detector offers protection against a wide range of hazardous industrial gases, including chlorine and hydrogen chloride, and is able to safeguard against oxygen deficiency. Designed for use in waste and wastewater treatment sites, the device features event logs, an LED display and explosion-proof housing. The system displays gas concentrations up to 500 ppm, fault codes for troubleshooting, and prompting when calibration is needed.
Moore Industries
Humidity and Temperature
The HTZ Smart HART
® Humidity and Temperature Transmitter from Moore Industries simultaneously measures temperature and humidity in closely monitored processes, such as those found in clean rooms, assembly areas, and storage facilities at pharmaceutical, semiconductor, food processing, and biotechnology facilities. HART communications allows the unit to be programmed or queried from any point along one of the transmitter’s dual 4-20mA loops. Accuracy of the relative humidity measurements is up to ±0.75%RH, the temperature measurements is up to ±0.036°C, and the dewpoint calculation is within ±0.5°C.
General Monitors
Gas Detector Calibration
Model S4000CH Combustible Gas Detector owners can calibrate this device with the new Automatic Remote Gas Calibrator from General Monitors. The unit, which allows calibration gas to be applied to the catalytic bead sensor from easily accessible locations, consists of a remote gas calibrator and a solenoid valve. The device blocks ambient air and redirects the calibration gas to the catalytic bead sensor for calibration or testing sensor accuracy. It can calibrate gases at wind velocities as high as 50 mph and maximum temperatures of 75°C.